X-ray Protective Clothing Asset Management and Quality Control Management Practice

Authors

  • Pengcheng Zhou
  • Sunzhong Lin

DOI:

https://doi.org/10.6981/FEM.202506_6(6).0010

Keywords:

X-ray Protective Clothing; Lead Clothing; Quality Control Testing; Asset Management; Asset Labeling.

Abstract

This study aims to optimize the management of X-ray protective clothing and quality control testing program in hospitals by combining fixed asset information management methods to improve management quality and work efficiency. By comparing and contrasting a variety of asset labeling management methods, the preferred method is to post the asset two-dimensional code on the storage cabinet one by one, and by comparing and contrasting a variety of quality control testing methods such as digital gastrointestinal machine, CT, DSA, etc., the preferred method is to select the scanning-based testing method of the digital gastrointestinal machine and to formulate the end-of-life standard of the protective clothing. The results show that this study can significantly improve the degree of management refinement, realize the long-term effective correspondence of assets, and effectively improve the efficiency of quality control testing and information management level of X-ray protective clothing.

Downloads

Download data is not yet available.

References

[1] Manchikanti, L., et al. (2002). “Radiation exposure to the physician in interventional pain management.” Pain physician 5(4): 385–393.

[2] Mirowski, M. M. (2021). “NEW-OLD METHODS OF REDUCING AND MONITORING X-RAY EXPOSURE IN THE INTERVENTIONAL RADIOLOGY ENVIRONMENT.” Medycyna Pracy 72(1): 49–59.

[3] Zhang Huaqing, Zhang Jucheng, Lou Haifang, et al. Statistical analysis of radiation protection product testing results [J]. Medical Equipment, 2015, 28(01): 9-11.

[4] Tao Gongfu, Zhang Feng. Radiation protection evaluation in catheterization rooms [J]. Chinese Medical Equipment, 2014, 29(10): 115-116+159.

[5] Mao Liqing, Weng Zizhi, Xu Tingting, Ju Jieqin. Study on the Cleaning Effect of Lead-Coated Foam Cleaning Solution on the Surface of Interventional Radiation Protection Lead-Coated Garments [J]. Zhejiang Medical Education, 2021, 20(03): 46-48.

[6] Chu Yonghua, Zhu Fengjie, Wang Zhihong, et al. Medical Radiation Protection Product Testing System [J]. Chinese Journal of Biomedical Engineering, 2020, 39(03): 375-379.

[7] Ou Xiangming, Fan Yaohua. Testing and Research on the Attenuation Performance of X-ray Protective Clothing [C]//. Proceedings of the China Medical Equipment Conference and 2019 Medical Equipment Exhibition. [Publisher unknown], 2019: 86-90.

[8] Zhang Xuan, Li Mengfei, Li Dehong et al. Research Progress on Testing Methods for X-ray Lead Protective Clothing [J]. Chinese Journal of Radiation Medicine and Protection, 2021, 41(06): 475-479.

[9] Zhao Rui, Wen Yuqin, Wu Jinjie, Han Lu, and Guo Bin. Establishment of X-ray Lead Equivalent Measurement Radiation Quality and Energy Spectrum Simulation [J]. Journal of Metrology, 2022, 43(07): 960-964.

[10] Zhang Shihui. Structural Design Research of Medical Diagnostic X-ray Radiation Protective Clothing [D]. Donghua University, 2022.

[11] Lee, S. and D. Jang (2024). “A proposal for the performance evaluation of 0.5 mm lead aprons used in nuclear medicine.” Radiation Protection Dosimetry 200(4): 333–338.

[12] Revathy, P. and S. B. Kaginelli (2023). “Quality assurance of lead aprons for radiation protection.” Radiation Protection Dosimetry 199(20): 2491–2494.

[13] Isobe, A., et al. (2019). “Construction of Management System Using Application Software for X-ray Protective Clothing Management.” Japanese Journal of Radiation Protection Technology 75(6): 546–552.

Downloads

Published

2025-06-12

Issue

Section

Articles

How to Cite

Zhou, P., & Lin, S. (2025). X-ray Protective Clothing Asset Management and Quality Control Management Practice. Frontiers in Economics and Management, 6(6), 81-89. https://doi.org/10.6981/FEM.202506_6(6).0010